MASTER LOAD 750
OPERATORS MANUAL
IM575
May, 2006
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
For use with equipment code number 10401.
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © 2005 Lincoln Global Inc.
RETURN TO MAIN MENU
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - MASTER LOAD 750

MASTER LOAD 750OPERATORS MANUALIM575May, 2006Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in min

Página 2 - WELDING EQUIPMENT SAFETY

GENERAL DESCRIPTIONThe Master Load 750 Load Bank is designed for elec-trically loading and testing power sources. The unit isdesigned for production l

Página 3

3INSTALLATION MASTER LOAD 7503BEFORE INSTALLATIONInspect the Load Bank for obvious damage such asbroken wires, broken or dented panels, crackedceram

Página 4

4OPERATION4PURPOSE AND USE OF CONTROLS1. POWER ON/OFF switch - Turns on cooling fanand powers remainder of control circuit. Red lightshows POWER ON.2.

Página 5

5MAINTENANCE5SAFETY PRECAUTIONSBefore servicing, read and observe all safetyprecautions throughout this manual. ELECTRIC SHOCK can kill.• Only qualif

Página 6 - LOAD BANK SAFETY

6TROUBLESHOOTING & REPAIR6MASTER LOAD 750If for any reason you do not understand the test procedures or are unable to perform the tests/repairs sa

Página 7 - Thank You

7TROUBLESHOOTING & REPAIR7MASTER LOAD 750Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the

Página 8 - TABLE OF CONTENTS

8TROUBLESHOOTING & REPAIR8MASTER LOAD 750Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the

Página 9

9TROUBLESHOOTING & REPAIR9MASTER LOAD 750Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the

Página 10 - DESCRIPTION

10DIAGRAMS10MASTER LOAD 750D263003-5-97MASTERLOAD 750 - WIRING DIAGRAM

Página 11 - INSTALLATION

11DIAGRAMSMASTER LOAD 75011SB25612-22-96MASTERLOAD 750 - DIMENSION PRINT

Página 12 - OPERATION

iiFOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be runnin

Página 13 - MAINTENANCE

PARTSMASTER LOAD 750D26244 SHT 1 & 23-6-97MASTERLOAD 750 - GENERAL ASSEMBLY

Página 14 - TROUBLESHOOTING & REPAIR

1 Base, Load Bank M18720 1 X2 Side Panel, (Left) M18720-1 1 X3 Side Panel, (Right) M18720-2 1 X4 Venturi, Fan M18720-3 1 X5 Rail (For Relay K8 Mtg.) M

Página 15

49 Bushing, Seal M18720-44 1 X50 Spring M18720-45 42 X51 Switch, Temp {S11} M18720-46 1 X52 - -53 Nut Assembled Washer M18720-47 84 X54 Threadlocker

Página 19

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Página 20 - MASTER LOAD 750

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Página 21

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Página 22

iiiiWELDING EQUIPMENT SAFETYARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of

Página 23

iiiiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Insta

Página 24

ivWELDING EQUIPMENT SAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instruc-tions et les précautions de sûreté s

Página 25

vLOAD BANK SAFETYvThe load bank is an industrial test unit designed to beused indoors or outdoors (sheltered from moisture).However, because the natur

Página 26

viMASTER LOAD 750viThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company p

Página 27

MASTER LOAD 750viiTABLE OF CONTENTSDESCRIPTIONTECHNICAL SPECIFICATIONS......

Página 28

1MASTER LOAD 750182 dBA at 3 ftDESCRIPTIONTECHNICAL SPECIFICATIONS – MASTER LOAD 750INPUT – POWERLOAD CAPABILITYPROTECTION FUSESCOOLING BLOWERHeight

Comentários a estes Manuais