Lincoln Electric VANTAGE 575 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Sistema de solda Lincoln Electric VANTAGE 575. Lincoln Electric VANTAGE 575 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
February, 2003
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and
built with safety in mind.
However, your overall safety
can be increased by proper
installation . . . and thoughtful
operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. Most
importantly, think before you
act and be careful.
OPERATOR’S MANUAL
Copyright© 2003 Lincoln Global Inc.
• World’s Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Sydney, NSW, Australia Tel: 02 9772 7222 Fax: 02 9792 2420
Cleveland, Ohio 44117-1199 USA Tel: 216.481.8100 Fax: 216.486.1751 Web Site: www.lincolnelectric.com
Date of Purchase: __________
Serial Number: _____________
Code Number: _____________
Model: ___________________
Where Purchased:__________
IM744
For use with machines having Code Numbers: 10905
Vantage 575
RETURN TO MAIN MENU
Vista de página 0
1 2 3 4 5 6 ... 53 54

Resumo do Conteúdo

Página 1 - Vantage 575

February, 2003Safety Depends on YouLincoln arc welding and cuttingequipment is designed andbuilt with safety in mind.However, your overall safetycan b

Página 2 - FOR ENGINE

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section

Página 3 - ARC RAYS can burn

TECHNICAL SPECIFICATIONS - Vantage 575 (K2170-1)INPUT - DIESEL ENGINEMake /Model Description Speed (RPM) Displacement Starting CapacitiesSystemCummins

Página 4 - SAFETY iii

Read this entire installation section before you startinstallation.SAFETY PRECAUTIONSDo not attempt to use this equipment until you havethoroughly rea

Página 5 - SAFETY iv

LIFTINGThe Vantage lift bale should be used to lift the machine. TheVantage is shipped with the lift bale retracted. Before attemptingto lift the Vant

Página 6 - WELDING, EMF & PACEMAKERS

PRE-OPERATION ENGINE SERVICEREAD the engine operating and maintenance instructionssupplied with this machine.• Keep hands away from the engine muffler

Página 7 - SAFETY vi

The Vantage is shipped with the negative battery cabledisconnected. Before you operate the machine, make sure theEngine Switch is in the OFF position

Página 8 - Thank You

REMOTE CONTROLOUTPUTThe Vantage is equipped with a 6-pin and a 14-pin connector. The6-pin connector is for connecting the K857 or K857-1 RemoteControl

Página 9

A-7 INSTALLATION A-7Vantage 575CONNECTION OF LINCOLN ELECTRICWIRE FEEDERSShut off welder before making any electrical connections.--------------------

Página 10 - TABLE OF CONTENTS

CONNECTION OF THE LN-25 TO THE VANTAGEThe LN-25 with or without an internal contactor may be used withthe Vantage. See the appropriate connection diag

Página 11 - INSTALLATION A-1

SAFETY INSTRUCTIONSRead and understand this entire section before operatingyour Vantage.Do not attempt to use this equipment until you havethoroughly

Página 12 - INSTALLATION A-2

ELECTRIC ANDMAGNETIC FIELDSmay be dangerous2.a.Electric current flowing through any conductor causeslocalised Electric and Magnetic Fields (EMF). Weld

Página 13 - INSTALLATION A-3

ENGINE CONTROLS (Items 1 through 9)1. RUN STOP SWITCHToggling the switch to the RUN position energizes the fuelsolenoid for approximately 30

Página 14 - INSTALLATION A-4

6. OIL PRESSURE GAUGE The gauge displays the engine oil pressure when the engine isrunning.7. ENGINE PROTECTIONThe yellow engine protection light rema

Página 15 - INSTALLATION A-5

WELDING CONTROLS (Items 10 through 19)10. OUTPUT CONTROL: The OUTPUT dial is used to preset theoutput voltage or current as displayed on the digital m

Página 16 - INSTALLATION A-6

21. CIRCUIT BREAKERSThese circuit breakers provide separate overload currentprotection for each 220V receptacle, the 42VAC AND 115VAC inthe 14-Pin con

Página 17 - INSTALLATION A-7

B-6 OPERATION B-6Vantage 575BREAK-IN PERIODThe engine used to supply power for your welder is a heavy duty,industrial engine. It is designed and built

Página 18 - INSTALLATION A-8

Table B.3 TYPICAL CURRENT RANGES (1)FOR TUNGSTEN ELECTRODES (2)DCEN (-) DCEP (+) Approximate Argon Gas Flow Ratel/min (c.f.m.)TungstenElectrode 1%, 2%

Página 19 - OPERATION B-1

CV-WIRE MODEConnect a wire feeder to the Vantage and set welder controlsaccording to the instructions listed earlier in this section.The Vantage in t

Página 20 - OPERATION B-2

B-9 OPERATION B-9Vantage 575TABLE B.4 Vantage Simultaneous Welding and Power Loads* Each receptacle is limited to 15 amps.TABLE B.5 Vantage Extension

Página 21 - OPERATION B-3

OPTIONAL FIELD INSTALLED ACCESSORIESKA1373 POWER PLUG KIT - Provides a plug for eachreceptacle.K857 8.5m or K857-20 20m (100ft.) REMOTE CONTROL -Porta

Página 22 - OPERATION B-4

SAFETY PRECAUTIONS• Have a qualified technician do the maintenance andtroubleshooting work.• Turn the engine off before working inside the machine.• R

Página 23 - OPERATION B-5

ELECTRIC SHOCKcan kill.3.a. The electrode and work (or ground) circuitsare electrically “hot” when the welder is on.Do not touch these “hot” parts wit

Página 24 - OPERATION B-6

7. Inspect for holes and tears by looking through the elementtoward a bright light. Check for damaged gaskets or dentedmetal parts. Do not reuse damag

Página 25 - OPERATION B-7

CHARGING THE BATTERYWhen you charge, jump, replace, or otherwise connect batterycables to the battery, be sure the polarity is correct. Improperpolari

Página 26 - OPERATION B-8

This Troubleshooting Guide is provided to help you locate andrepair possible machine malfunctions. Simply follow the three-step procedure listed below

Página 27 - OPERATION B-9

E-2 TROUBLESHOOTING E-2Observe all Safety Guidelines detailed throughout this manualVantage 575CAUTIONºIf for any reason you do not understand the tes

Página 28 - ACCESSORIES C-1

CAUTIONVantage 575E-3 TROUBLESHOOTING E-3If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely

Página 29 - MAINTENANCE D-1

PROBLEMS(SYMPTOMS)Engine goes to low idle but does not stay atlow idle.No welding output or auxiliary output.Welder has some/ no output and no control

Página 30 - MAINTENANCE D-2

F-1 DIAGRAMS F-1Vantage 575NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific dia-

Página 31 - MAINTENANCE D-3

Vantage 575F-2 DIAGRAMS F-2CONNECTION DIAGRAM:

Página 32 - TROUBLESHOOTING E-1

F-3 DIAGRAMS F-3Vantage 575CONNECTION DIAGRAM:GND757677GREENK291 OR K40475INPUT CABLE76N.E.77K775 OPTIONALREMOTE CONTROLDAMAGED. THE ENGINE GOVERNOR S

Página 33 - TROUBLESHOOTING E-2

F-4 DIAGRAMS F-4Vantage 575CONNECTION DIAGRAM

Página 34 - TROUBLESHOOTING E-3

FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working on theequipment.8.b.Install equi

Página 35 - TROUBLESHOOTING E-4

Vantage 575F-5 DIAGRAMS F-5CONNECTION DIAGRAM

Página 36 - DIAGRAMS F-1

Vantage 575F-6 DIAGRAMS F-6CONNECTION DIAGRAMCAUTION :N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND F

Página 37 -

Vantage 575F-7 DIAGRAMS F-7CONNECTION DIAGRAM

Página 38 - DIAGRAMS F-3

Vantage 575F-8 DIAGRAMS F-8CONNECTION DIAGRAM

Página 39 - DIAGRAMS F-4

Vantage 575F-9 DIAGRAMS F-9CONNECTION DIAGRAMor service this equipment.Only qualified personnel should install,useKeep away from moving parts.Keep gua

Página 40

Vantage 575F-10 DIAGRAMS F-10CONNECTION DIAGRAM

Página 41 - DIAGRAMS F-6

Vantage 575F-11 DIAGRAMS F-11CONNECTION DIAGRAM

Página 42 - DIAGRAMS F-7

Vantage 575F-12 DIAGRAMS F-12CONNECTION DIAGRAM

Página 43

Vantage 575F-13 DIAGRAMS F-13CONNECTION DIAGRAM

Página 44 - DIAGRAMS F-9

Vantage 575F-14 DIAGRAMS F-14DIMENSION PRINTTRAILER MOUNTING HOLE LOCATIONS.*28.99736.319.63498.66.55166.423.69601.750.381279.754.441382.814.63371.637

Página 45

iv SAFETY ivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui par

Página 46

NOTESVantage 575

Página 47

NOTESVantage 575

Página 48

Vantage 575WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURE

Página 49 - DIAGRAMS F-14

Vantage 575WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO

Página 50

World’s Leader in Welding and Cutting Products• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 USA Tel:

Página 51

v SAFETY vWELDING, EMF & PACEMAKERSAll welders should follow safe practices that minimise theirexposure to electric and magnetic fields (EMF).For

Página 52

This welding machine must be used by trained operatorsonly. Read this manual carefully before attempting to use thewelding machine.ConformanceProducts

Página 53 - ATTENTION

WARNINGvii viiThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company produc

Página 54

PageSafety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i-v

Comentários a estes Manuais

Sem comentários